1991 · Система охлаждения — страница 2

REFILLING · 2

1991-Montero-Service-Manual · general cooling system servicing · страница 2 из 3 · Открыть оригинал PDF ↗

REFILLING

To prevent air from being trapped in engine block, engine
should be running when refilling cooling system. After system is full,
continue running engine until thermostat is open, then recheck fill
level. Do not overfill system.

TESTING

Термостат

1) Visually inspect thermostat for corrosion and proper
sealing of valve and seat. If okay, suspend thermostat and thermometer
in a 50/50 mixture of coolant and water. See Fig. 1. Do not allow
thermostat or thermometer to touch bottom of container. Heat water
until thermostat just begins to open.

2) Read temperature on thermometer. This is the initial
opening temperature and should be within specification. Continue
heating water until thermostat is fully open and note temperature.
This is the fully opened temperature. If either reading is not to
specification, replace thermostat.

Иллюстрация 1, страница 2
Иллюстрация 2, страница 2
Иллюстрация 3, страница 2
Иллюстрация 4, страница 2
Иллюстрация 5, страница 2
Иллюстрация 6, страница 2
Иллюстрация 7, страница 2
Иллюстрация 8, страница 2
Иллюстрация 9, страница 2
Иллюстрация 10, страница 2
Иллюстрация 11, страница 2
Иллюстрация 12, страница 2
Иллюстрация 13, страница 2
Иллюстрация 14, страница 2
Иллюстрация 15, страница 2

Fig. 1: Testing Thermostat in Anti-Freeze/Water Solution

PRESSURE TESTING

A pressure tester is used to check both radiator cap and