1989-Mitsu-Factory Manual · heaters AC · страница 13 из 16 · Открыть оригинал PDF ↗
BLOWER ASSEMBLY
REMOVAL AND INSTALLATION
Removal steps
1. Lap heater duct (C)
2. Glove box
++ I)+ 3. Air selection control wire
4. Duct
*I) 5. Blower assembly
6. Resistor
7. Hose
8. Blower motor
9. Packing
IO. Fan

TE
Reverse the removal procedures to reinstall.
** : Refer to ‘Service Points of Removal”.
** : Refer to “Service Points of Installation”
N24K6A
SERVICE POINTS OF REMOVAL
3. REMOVAL OF AIR SELECTION CONTROL WIRE
(1) Use a screwdriver to pry and remove the clip that
holds the outer cable of the air selection control wire.
(2) Disconnect the inner cable of the air selection control
wire from the end of the air selection damper lever.

5. REMOVAL OF BLOWER ASSEMBLY
(I) Disconnect the connector of the front wiring harness
(connected to the resistor).
(2) Remove the ground installation bolt. (Tightened togeth-
er with the blower assembly.)
(3) Remove the blower assembly installation bolt.

Проверка
NZMCAD
RESISTOR
Connect an ohmmeter to each terminal of the resistor and
measure the resistance.
| Terminal connections | Resistance |
|---|---|
| I-2(M,) | Approx. 1.22n |
| 1-3(Mz) | Approx. 0.41R |
| I I-4(Low) I | Approx. 2.250 I |
| 1 -5(High) | Approx. OQ |
| a I n I |