1989-Mitsu-Factory Manual · wiper washer system · страница 12 из 19 · Открыть оригинал PDF ↗

Стеклоочистители и омыватели
INTERMilTENT WIPER RELAY
Remove the intermittent wiper relay (located at the upper
part of the left side cowl side trim).


CONTINUITY CHECK
Check to see that there is continuity between terminals 2
and 5.





INTERMITTENT OPERATION CHECK

(1) Connect the battery and the test light to the relay, as
shown in the figure.
(2) Insert a variabie resistance between terminal 8 and bat-
tery (-1 (VR = G-50 kfi)
(3) The condition is normal if, when the battery’s negative
(-) terminal is connected to terminal 7, the test light
illuminates at the same time, and thereafter, in accord-
ance with the value of the variable resistance, stops
illumination (approx. 1.5 -sec. - approx. 10.5 sec.) and
then illuminates (approx. 1 sec.) over and over again.
WASHER INTERLOCK OPERATION CHECK
(1) Connect the battery and the test light to the relay, as
shown in the figure.
(2) When terminal 3 is connected to the battery’s negative
(-) terminal, the test light will illuminate approximately 1
second thereafter, and then there will be a release for
about seconds after connecting to the battery’s negative
(-) terminal.
(3) The condition is normal if about 3 seconds thereafter the
test light stops illumination.