8-18 INSPECTION OF HARNESS CONNECTOR · 18

8-18 INSPECTION OF HARNESS CONNECTOR · 18

1989-Montero · elect contents locations · страница 18 из 20 · Открыть оригинал PDF ↗

8-18 INSPECTION OF HARNESS CONNECTOR -

INSPECTION OF HARNESS CONNEClom CONTINUITY AND VOLTAGE TEST FOR CONNECTOR

Following procedures shall be followed for testing continuity
and voltage at connector in order to prevent improper contact
and deterioration of waterproof in connector.

CONVENTIONAL (NON-WATERPROOF) CONNECTOR

Check shall be done by inserting a probing needle from
harness side.

WATER PROOF CONNECTOR

Caution

Do not insert probing needle from harness side as it will
deteriorates waterproof and cause for rusting. To inspect
the energized circuit, use the ECI checker.

Иллюстрация 1, страница 18

Connector which gives loose engagement shall be rectified
by removing female terminal from connector housing and
raise its lance to establish securer engagement. Removal of
connector housing and raise its lance to establish securer
engagement. Removal of connector terminal used for ECI
and ELC 4 A/T control circuit shall be done in the following
manner.

COMPUTER CONNECTOR

(I) Insert screwdriver [I.4 mm (.06 in.) width] as shown in
the figure, disengage front holder and remove it.

(2) Insert harness of terminal to be rectified deep into
connector from harness side and hold it there.

Иллюстрация 2, страница 18
Иллюстрация 3, страница 18
Иллюстрация 4, страница 18