1987-Montero · Cooling a · страница 2 из 18 · Открыть оригинал PDF ↗

GENERAL INFORMATlON
The cooling system is a water cooling type and the coolant is forcibly circulated by the water pump. The
temperature control of the coolant is conducted by the thermostat installed in the intake manifold.
Immediately after engine starting, the coolant does not flow into the radiator until the coolant temperature
reaches the thermostat valve opening temperature. The coolant circulates in the engine and it is promptly
warmed up to the proper temperature, and at the same time, the temperature of the coolant in the cylinder
block and cylinder head is made uniform. When the coolant temperature rises and the thermostat valve
opens, the coolant flows into the radiator. The coolant cooled by the radiator is pumped up and pressurized
by the water pump and delivered to the cylinders and cools the engine. Also, the cooling fan is installed at
the water pump pulley and reduces the coolant temperature inproportion to the engine revolution.
Furthermore, between the fan and pulley, the fan clutch is installed, which reduces the engine output loss
and noise.