CHARGING SYSTEM - Alternator
STATOR
l Make continuity test on stator coil. Check to ensure that
there is continuity between coil leads.
If there is no continuity, replace stator assembly.

l Check coil for grounding. Check to ensure that there is no
continuity between coil and core. If there is continuity,
replace stator assembly.


RECTIFIERS
l Positive rectifier test
Check for continuity between positive rectifier and stator
coil lead connection terminal with a circuit tester. If there
is continuity in both directions, diode is shorted.
Replace rectifier assembly.

e Negative rectifier test
Check for continuity between negative rectifier and stator
coil lead connection terminal. If there is continuity in both
direction, diode is shorted, and rectifier assembly must
be replaced.

e Diode trio test
Check three diodes for continuity by connecting a circuit
tester to both ends or each diode. If there is no continuity
or no continuity in both directions, diode is defective and
heatsink assembly must be replaced.