exists in wire between alternator terminal "S" and positive battery
terminal or fusible link is blown.

4) Start engine. Ensure all lights and accessories are off.
Operate engine at 2500 RPM and read voltmeter when alternator output
current drops to 10 amps or less. Voltage regulator is okay if voltage
output is within specification. See REGULATOR VOLTAGE SPECIFICATIONS
table.

BENCH TESTING

RECTIFIER ASSEMBLY

1) Using ohmmeter, check for continuity between both diodes
and stator coil lead connection. See Fig. 11. Reverse leads. If
continuity exists in both directions, diode is shorted. Replace
rectifier assembly.

2) To check entire diode assembly, use an ohmmeter to check
for continuity between both ends of each diode. See Fig. 11. Switch
ohmmeter leads. Continuity should exist in one direction, but not
other. If no continuity exists or continuity exists in both
directions, diode is defective. Replace rectifier assembly.

Иллюстрация 1, страница 12
Иллюстрация 2, страница 12
Иллюстрация 3, страница 12
Иллюстрация 4, страница 12
Иллюстрация 5, страница 12
Иллюстрация 6, страница 12
Иллюстрация 7, страница 12
Иллюстрация 8, страница 12
Иллюстрация 9, страница 12
Иллюстрация 10, страница 12
Иллюстрация 11, страница 12
Иллюстрация 12, страница 12
Иллюстрация 13, страница 12
Иллюстрация 14, страница 12

Fig. 11: Testing Rectifier Assembly
Courtesy of Mitsubishi Motor Sales of America.

Оригинальная страница руководства
exists in wire between alternator terminal "S" and positive battery
100%

Назад
Сверху