SERVICE ADJUSTMENT PROCEDURES · 10 — Pajero II 1991–1998 — руководство по ремонту

SERVICE ADJUSTMENT PROCEDURES · 10

SERVICE ADJUSTMENT PROCEDURES · 10

1998 · EMISSION CONTROL [17] · страница 10 из 14 · Открыть оригинал PDF ↗

Текст распознан со скана. Числа и обозначения можно сверить с оригиналом ниже.

Purge Control Solenoid Valve Inspection NOTE

When disconnecting the vacuumhose,make an identification
mark on it So that it can be reconnected to the original
position

(1) Disconnect the vacuum hose (black with red stripe) from
the solenoid valve

2)Disconnect the harness connector:

3) Connect a hand vacuum pump to the nipple to which the
red-striped vacuum hose was connected.

Apply a vacuum and check for air-tightness when voltage
is applied directly to the purge-control solenoid valve and
when the voltage is discontinued;

Таблица в оригиналеТаблица: оригинал страницы 10
Распознанный текст таблицы — требует сверки с оригиналом
Battery voltageNormal condition
When appliedVacuum leaks
When discontinuedVacuum is maintained
Иллюстрация 1, страница 10

(5) Measure the resistance between the terminals of the
solenoid valve

Standard value: 2127 @ [at 20*C]

EXHAUST EMISSION CONTROL SYSTEM

AIR FUEL RATIO CONTROL SYSTEM

To inspect the air-fuel ratio control system, refer to
GROUP 13.

For detailed information concerning the illumination
pattern of the malfunction-indicator light and other aspects
of the self-diagnosis function, refer to GROUP 13.