1991 · Проверка компонентов системы — страница 4

INTAKE AIR TEMP SENSOR RESISTANCE TABLE · 4

1991-Montero-Service-Manual · system component tests · страница 4 из 18 · Открыть оригинал PDF ↗

INTAKE AIR TEMP SENSOR RESISTANCE TABLE

Temperature
°F (°C) Ohms

All Models

32 (0) ........................ 6000
68 (20) ....................... 2700
176 (80) ....................... 400

MOTOR POSITION SENSOR

NOTE: Some engines are not equipped with Motor Position Sensor

(MPS). MPS may be a separate unit mounted to throttle body
or it may be incorporated in ISC motor assembly, depending
upon vehicle application.

Pickup 2.4L & Ram-50 2.4L

1) Disconnect MPS connector. See Fig. 2. Connect ohmmeter
lead to ground. Connect other ohmmeter lead to terminal No. 3 of
sensor connector. If continuity is not present, repair wiring harness
as necessary. If continuity is present, go to next step.

Иллюстрация 1, страница 4
Иллюстрация 2, страница 4
Иллюстрация 3, страница 4
Иллюстрация 4, страница 4
Иллюстрация 5, страница 4
Иллюстрация 6, страница 4
Иллюстрация 7, страница 4
Иллюстрация 8, страница 4
Иллюстрация 9, страница 4
Иллюстрация 10, страница 4
Иллюстрация 11, страница 4
Иллюстрация 12, страница 4
Иллюстрация 13, страница 4
Иллюстрация 14, страница 4
Иллюстрация 15, страница 4
Иллюстрация 16, страница 4
Иллюстрация 17, страница 4
Иллюстрация 18, страница 4
Иллюстрация 19, страница 4
Иллюстрация 20, страница 4
Иллюстрация 21, страница 4

Fig. 2: Motor Pos. Sensor Connector Term. ID
Courtesy of Mitsubishi Motor Sales of America.

2) Connect ohmmeter leads to terminals No. 2 and 3.
Resistance should be 4000-6000 ohms. If resistance is not within