valve nipple where Red-striped hose was connected. Apply vacuum to
solenoid valve. Vacuum should hold.
2) Apply battery voltage to terminals of solenoid valve.
Vacuum should bleed down when voltage is applied to terminals. Using
an ohmmeter, check resistance across solenoid valve terminals. Reading
should be 36-44 ohms at 68�F (20�C). If reading is not within
specification, replace valve.

POSITIVE CRANKCASE VENTILATION (PCV)

PCV Valve

Remove PCV valve, and insert thin screwdriver into threaded
end of valve to ensure plunger moves.