1998 · BODY [42] · страница 8 из 14 · Открыть оригинал PDF ↗
Текст распознан со скана. Числа и обозначения можно сверить с оригиналом ниже.
POWER WINDOW OPERATION CURRENT INSPECTION
Remove the power windowfuseand connecta circuit
analyser as shown in the illustration
2When the power window switch is pressed to the UP
position, a large amount of current flows atthetime the
window starts to close and when it is fully closed,SO
measure the operation current in the interval between
these two points.
Standard value:
A (for 1415 V power supply voltage at
258C)
3If the operation current is outside the standard value, refer
to"Troubleshooting" (P.42-2).
CiRCUIT BREAKER (INCORPORATED IN THE POWER WINDOW MOTOR) INSPECTION
Press the power window switch to the UP position tofully
close the window glass, and keep pressing the switch for
a further 10 seconds
2Release the power window switch from the UP position
and immediately press it to the DOWN position_The
condition of the circuit breaker is good if the power
window glass starts to move downwards within 60
seconds_