1989-Montero · fuel system · страница 33 из 53 · Открыть оригинал PDF ↗
ELECTRIC CHOKE RELAY
Проверка
(1) Remove the cover of the device box and remove the
electric choke relay.
(2) Check for continuity between terminals when there is and
is not current flow to the relay coil.

| Item | Measured terminals | Continuity |
|---|---|---|
| Between terminals 0-Q | Yes (M) | |
| No power flow | Between terminals 0-Q | No (ma) |
| Between terminals 0 * @ | Yes (approx. 1 OOi2) | |
| Between terminals @ - @ | Yes (On) | |
| Power flow | Between terminals 0 - @ | No (a-l) |
NOTE
1. + indicates the current flow direction.
2. inspect after checking the infinity of tester.
3. Tonenergize the relay coil, apply battery voltage directly to
terminals 0.
4. Use care as application of battery voltage to incorrect
terminals can cause damage to the relay.
(3) If the continuity test fails, replace the electric choke relay.
NOTE
If the electric choke body remains cool after engine start al-
though the electric choke heater (PTC heater) and electric
choke relay are normal, check the vehicle body harness circuit.