1989-Montero · emission system · страница 27 из 38 · Открыть оригинал PDF ↗
Проверка
(1) Referring to the VACUUM HOSES ROUTING. confirmy
the vacuum hoses are properly connected.
(2) Check the hoses for irregularities (disconnection, loo-
seness, etc.) and confirm that there is no breakage or
damage.
INSTALLATION
NZSJDAU
(1) When connecting a hose, firmly press if onto the nipple.
(2) Referring to the VACUUM HOSES ROUTING, connect the
hoses correctly.
CRANKCASE EMISSION CONTROL SYSTEM COMPONENTS LOCATION
Nz5!A-I3






POSITIVE CRANKCASE VENTILATION (PCW VALVE
For information concerning the checking of the positive
crankcase ventilation valve, refer to GROUP 0 - Maintenance
Service.
REMOVAL
(1) Remove the air intake plenum. (Refer to GROUP 11 - Air
Intake Plenum.)
(2) Remove the positive crankcase ventilation valve.
INSTALLATION
(I) Install the positive crankcase ventilation valve and tighten
to specified torque.
Specified tightening torque : 8-12 Nm (6-g ft.lbs.)
(2) Install the air intake plenum. (Refer to GROUP 11 - Air
Intake Plenum.)