BLOWER SWITCH · 3

BLOWER SWITCH · 3

1991-Montero-Service-Manual · heater system · страница 3 из 14 · Открыть оригинал PDF ↗

With lever set at OUTSIDE position, outside air is allowed to enter
and/or pass through heater. With lever set at INSIDE position, air is
recirculated inside passenger compartment.

BLOWER SWITCH

The blower can be operated at different fan speeds to
regulate amount of air forced through vehicle. Fan speed will increase
as switch is turned or moved right.

AIR CONTROL INDICATION SYSTEM

This system consists of indication lights built into
instrument cluster and 4 switches connected to various control levers.
An indication light glows when heater blower is on. Lights also
indicate choice of outlets and whether air source is inside or outside
vehicle. In addition, temperature of air directed from outlets is
indicated for each air outlet by light colors of green (cool air) and
orange (warm air).

ADJUSTMENTS

HEATER (TEMPERATURE) CONTROL VALVE

Place control lever to indicated position. See TEMPERATURE
CONTROL CABLE ADJUSTMENT table. See Fig. 3. Connect cable to heater
control valve and/or air damper lever according to table. Secure cable
sleeve using clips. With engine running, check for coolant leaks and
check operation of heater control valve. If heater control valve does
not operate properly, adjust by moving cable sleeve forward or
backward at retaining clip.

TEMPERATURE CONTROL CABLE ADJUSTMENT TABLE

Application Control Lever Water Valve
Position Lever Position
Montero .................... Far Left ............... Toward cable
Pickup & Ram-50 ............ Far Left ........ (2) Away from cable
Таблица в оригиналеТаблица: оригинал страницы 3

(2) - Disconnect link between air damper lever and water valve
lever. Close water valve. Close air damper. Reconnect link.
Attach cable to clip.

Иллюстрация 1, страница 3
Иллюстрация 2, страница 3
Иллюстрация 3, страница 3

Fig. 3: Adjusting Temperature Control Cable (Typical)
Courtesy of Mitsubishi Motor Sales of America.

INSIDE/OUTSIDE AIR SELECTION CABLE

Оригинальная страница руководства
With lever set at OUTSIDE position, outside air is allowed to enter
100%

Назад
Сверху