1991-Montero-Service-Manual · heater system · страница 8 из 14 · Открыть оригинал PDF ↗
Disconnect harness connector from resistor terminals. Using
an ohmmeter, check resistance between terminals indicated in BLOWER
MOTOR RESISTOR RESISTANCE table. See Fig. 8. If resistance is not as
shown, replace resistor.
BLOWER MOTOR RESISTOR RESISTANCE TABLE
Terminal Nos. Ohms
| Montero | |
|---|---|
| 1-2 | ..................................... 1.22 |
| 1-3 | ...................................... .41 |
| 1-4 | ..................................... 2.25 |
| 1-5 | ........................................ 0 |
| Pickup | & Ram-50 |
| 1-2 | ..................................... 1.19 |
| 1-3 | ...................................... .50 |
| 1-4 | ..................................... 2.33 |
| 1-5 | ........................................ 0 |
























Fig. 8: Identifying Blower Resistor Terminals
Courtesy of Mitsubishi Motor Sales of America.
REMOVAL & INSTALLATION
HEATER CORE