NO TEMPERATURE REGULATION · 5

NO TEMPERATURE REGULATION · 5

1991-Montero-Service-Manual · heater system · страница 5 из 14 · Открыть оригинал PDF ↗

Incorrect thermostat in cooling system. Improperly adjusted
temperature control cable. Clogged heater core fins. Faulty heater
control valve.

NO TEMPERATURE REGULATION

Clogged or stuck heater control valve. Incorrect installation
of heater control valve control cable. Incorrect adjustment of heater
control valve link.

NO VENTILATION

Incorrect adjustment of change-over dampers. Duct connection
loose.

TESTING

BLOWER MOTOR SWITCH TEST

Blower motor switch can be tested using an ohmmeter. Insert
test leads into appropriate connector terminals, and check continuity.
See BLOWER SWITCH CONTINUITY table. See Fig. 5 or 6.

BLOWER MOTOR SWITCH CONTINUITY TABLE

Continuity Between
Switch PositionTerminal Nos.
Montero
Low ................................ 1-2 & 1-7
Medium 1 ........................... 2-4 & 4-7
Medium 2 ........................... 2-5 & 5-7
High ............................... 2-6 & 6-7
1992 Montero
Low ................................ 1-8 & 3-5
Medium 1 ........................... 1-8 & 5-6
Medium 2 ...................... 1-4, 1-8 & 2-5
High .......................... 1-4, 1-8 & 5-7
Pickup & Ram-50
Low ........................... 1-2, 2-6 & 7-8
Medium 1 ...................... 1-3, 3-6 & 7-8
Medium 2 ...................... 1-4, 4-6 & 7-8
High .......................... 1-5, 5-6 & 7-8
Таблица в оригиналеТаблица: оригинал страницы 5
Иллюстрация 1, страница 5
Иллюстрация 2, страница 5
Иллюстрация 3, страница 5
Иллюстрация 4, страница 5

Fig. 5: Blower Motor Switch Connector Terminal ID (Pickup & Ram-50)
Courtesy of Mitsubishi Motor Sales of America.

Оригинальная страница руководства