1991-Montero-Service-Manual · heater system · страница 4 из 14 · Открыть оригинал PDF ↗
Move control lever to INSIDE position. Connect cable to
damper lever with outside air intake to heater closed. Apply
multipurpose grease to rotating portions of sliding lever. Check for
proper damper operation by moving control lever. To adjust, press air
control lever toward cable and move outer wire at retaining clip. See
Fig. 4.
























Fig. 4: Adjusting Air Selection Cable (Typical)
Courtesy of Mitsubishi Motor Sales of America.
MODE SELECTOR LEVER
Place selection lever in DEF position, and remove cable clip.
Ensure defroster door is fully open. Secure cable sleeve using clips.
Move lever to other positions to check for correct operation. Adjust
cable, if necessary, by moving sleeve forward or backward at retaining
clip.
TROUBLE SHOOTING
BLOWER MOTOR INOPERATIVE
Blown blower fuse. Blower motor improperly grounded.
Defective switch or faulty blower motor wiring connections. Foreign
object in fan.