1989-Montero · heaters AC · страница 6 из 16 · Открыть оригинал PDF ↗
HEATERS - Service Adjustment Procedures
(2) Turn the mode selection damper lever all the way in the
direction of the arrow.
(3) Pull the “VENT” damper lever completely downward
and move the “VENT” damper to the position (not
visible) shown in the figure.
(4) Attach the end of the link for the “VENT” damper to the
mode selection damper lever.

3. Adjust the “FOOT/DEF” damper as described below.
(1) Unfasten the clip of the mode selection damper lever,
and disconnect the link for the “FOOT/DEF” damper
from the mode selection damper lever.
(2) Turn the mode selection damper lever all the way in the
direction of the arrow.

(3) Pull the “FOOT/DEF” damper lever completely upward
and move the “FOOT/DEF” damper to the position
shown in the figure. (The packing should contact the
case.)
NOTE
Confirmation can be made that the “FOOTKIEF” damp-
er is raised upward through the defroster blower outlet
of the heater unit (with defroster duct disconnected).
(4) Attach the end of the link for the “FOOT/DEF” damper
to the mode selection damper lever.
NOTE
When attaching it, pull the lever end (A in the figure) in
the direction of the arrow.
4. Referring to the section which explains the adjustment of
the mode selection control wire, connect the control wire
to the mode selection damper lever.
TEMPERATURE CONTROL LEVER
1. Move the temperature control lever from its extreme left
position to its extreme right position and check to be sure
that it moves correctly and smoothly to each position.
2. Then move the temperature control lever to the extreme
left position, and check to be sure that warm air does not
come out when the blower is operated.
3. If the air flow is not correct in the above step, adjust the
temperature control wire.