If any one of the following switches and sensors is
turned off,the magnet clutch of the compressor is
turned off.
Распознанный текст таблицы — требует сверки с оригиналом
| Switch and sensor | Operating condition of compressor |
|---|---|
| Blower switch Air conditioner switch | Manual ON, OFF |
| Dual-pressure switch kPa (kg/cm? , psi) | |
| High pressure switch | OFF at 200 (2.0,28.4) or less, ON at 210 (2.1,29.9) or more |
| Low pressure switch | OFF at 2,700 (27,384) or more, ON at 2,000 (20,284) or less |
| Engine coolant temperature switch 'C(PF) (For air conditioner cut-off} | |
| Petrol-powered vehicles | OFF at 115 (239) or more, ON at 108 (226) or less |
| Diesel-powered vehicles | OFF at 116 (241) or more, ONat 109 (228) or less |
| Air inlet sensor Air thermo sensor | See the characteristic diagram |
Compressor Magnet Clutch Control Characteristic Diagram

HY101016-296