AIR-THERMO SENSOR AND AIR-INLET SENSOR

Disconnect the sensor's connector at the evaporator case and
by using an ohmmeter, measure the resistanceIf the resistance
is within 10% of value of the characteristic curve, the sensor is
functioning normally:
ENGINE COOLANT TEMPERATURE SWITCH <For air conditioner switch offz

(1)Diptheenginecoolant temperatureswitchinoiland
heat the oil witha gas burner or similar item:
(2)Whentheoil temperaturereachesthestandardvalue,
check that there isnocontinuity between the switch ter-
minals .
Standard value:<Except 4056 enginez
More than 112-118PC (234-2449F)
<4056>
More than 114-118PC (237-2449F)
<For condenser fan>
(1) Diptheenginecoolanttemperatureswitchinoilas
shown in the illustration.
(21Check the continuity witha circuit tester as the tempera-
ture of the oil changes, and the condition is normal if the
continuity is within the following ranges_
<4056>
Распознанный текст таблицы — требует сверки с оригиналом
| Item | Standard value |
|---|---|
| Continuity | More than |
| (temperature at point A) | 99 105*C (210-2219F) |
| No continuity | Less than |
| (temperature at point B) | 97*C (206'F) |
<4M4O>
Распознанный текст таблицы — требует сверки с оригиналом
| Item | Standard value |
|---|---|
| Continuity | More than |
| (temperature at point A) | 101-105*C (214-221*F) |
| No continuily | Less than |
| (temperature at point B) | 98'C (208*F) |
PWJE9086-E