Service Bulletins · MSB98E37002e · страница 12 из 12 · Открыть оригинал PDF ↗
<Deleted>
20. INSTALLATIONOF VALVE HOUSING
(1) Apply specified automatic transmission fluid to the seal
ring of the rack piston.
Specified fluid:Automatic transmission fluid
DEXRON or DEXRON II
(2) Insert the valve housing.
(3) Rotate the main shaft until the rack piston moves to the
neutral position (center).

24. INSTALLATION OF ADJUSTING PLATE/25. ADJUSTING BOLT
(1) Install the adjusting plate so that the beveled part is
facing downward.
(2) Using a thickness gauge, measure the clearance
between the adjusting bolt and cross-shaft.
Standard value:0 - 0.05 mm (0 – 0.002 in.)
(3) If the clearance is exceeded the standard value, replace
with a suitable adjusting plate.
26. INSTALLATIONOF CROSS-SHAFT/27. ADJUSTING BOLT LOCK NUT
Install the cross-shaft to the side cover, and then temporarily
tighten the adjusting bolt lock nut.

29. INSTALLATIONOF SIDE COVER AND CROSS-SHAFT ASSEMBLY
Install the side cover assembly (with the corss-shaft) to the
gear box.
NOTE
Apply specified automatic transmission fluid to the teeth and
shaft areas of the rack piston, and apply multipurpose
grease to the oil seal lip.
Specified fluid:Automatic transmission fluid DEXRON or DEXRON II
Caution
Do not rotate the side cover during installation. Take
care not to damage the cross-shaft oil seal.