HEATER (SeeP4-108,111,114.) OPERATION
(Front heater operation)
When the ignition switch is turned ON, the blower
relay is energized.If the blower switch is turned
ON (LO, ML, MH,or HI position) in this condition
thebloweris activated through thecircuitvia
resistor atspeed corresponding to the blower
switch position.
(Rear heater operation)
When the ignition switch is in the ON position and
the rear heater control switch is turned to ON, the
rear heater relay turns ON and the blower motor is
activated via the resistor at a speed corresponding
to the blower switch position (LO,M,HI).
TROUBLESHOOTING HINTS
Blower motor is energized at one switch position
andnotenergizedat another.
Check harness and connectors between defec-
tiveswitch positionandresistor (or blower
motor in Hl position) .
Blower motor is energized only when switch is
positioned in HI.
Check resistor.
3. Blower motor speed does not represent the switch
position.
Check blower switch.