1989 · Система кондиционирования — страница 19

AIR CONDITIONER SWITCH To Test the Air Conditioner Switch · 19

1989-Mitsu-Factory Manual · AC system · страница 19 из 42 · Открыть оригинал PDF ↗

AIR CONDITIONER SWITCH To Test the Air Conditioner Switch

(I) Ft;E;nect the harness connector for the air conditioner

(2) Jump ;he lead wires as shown.
(3) Turn the blower switch ON.

(4) Momentarily turn the ignition switch on (do not crank the en-
gine), listen for the clutch engaging.

Иллюстрация 1, страница 19

(5) If the clutch does not engage, fin thermostat, water
temperature switch, wiring or fuse may be faulty.
(6) If clutch engages, replace the air conditioner switch.

MAGNETIC CLUTCH

(1) Disconnect the wiring to the magnetic clutch.

(2) Connect battery (+) voltage directly to the wiring for the mag-
netic clutch.

‘(3) If the magnetic clutch is normal, there will be a “click”. If the
pulley and armature do not make contact (“click”), there is a
malfunction.

Иллюстрация 2, страница 19
Иллюстрация 3, страница 19

COMPRESSOR

(1) Install the manifold gauge set, and run the air conditioner.
(2) If a pressure of approx.490 kPa (71 psi) is indicated on the
suction gauge side and a pressure of approx.883 kPa (128 psi)
is indicated on the discharge gauge side, the compressor has
abnormal compression.
Replace the compressor.

(3) If a pressure of 294 to 392 kPa (43 to 59 psi) is indicated on the
suction gauge side and a pressure of approx.1961 kPa (284
psi) is indicated on the discharge gauge side, it is suspected
that air is present in the air conditioning system.
Discharge the system, evacuate and recharge with specified
amount of refrigerant.
Recharging condition

Иллюстрация 4, страница 19

l Cooler discharge temperature (evaporator) : 30-35°C
(86-95°F)

l Engine revolutions : 2,000 rpm
l Blower : HI

(4) During operation of the air conditioner, cold air may stop flow-
ing after the elapse of time and this state is maintained before
cold air flows out again. If cold air stops flowing out with
negative pressure indicated on the suction gauge side and a
pressure of 588 to 980 kPa (85 to 142 psi) indicated on the
discharge gauge side, it is suspected that water is present in
the air conditioning system.
Discharge the system. Replace receiver drier. Evacuate and
check for leaks, and recharge with specified amount of refrig-
erant.

Иллюстрация 5, страница 19
Иллюстрация 6, страница 19
Оригинальная страница руководства
AIR CONDITIONING - Service Adjustment Procedures
100%

Назад
Сверху