Caution
Electrbtype
leak tester Replacement filter-drier units must be sealed while in
storage. The drier used in these units will saturate water
quickly upon exposure to the atmosphere. When installing
a drier, have ali tools and supplies ready for quick
reassembly to avoid keeping the system open any longer
than necessary.
(7) Evacuate and charge the system.
LOW CHARGE
2OW848 If the system has not lost all of its refrigerant charge: locate
and repair all leaks. If it is necessary to increase the system
pressure to find the leak (because of an especially low charge)
add refrigerant. If it is possible to repair the leak without
discharging the refrigerant system, use the procedure for
correcting low refrigerant level.

Since the refrigeration system is completely sea-
led, refrigerant level will not be low unless there is
a leak in the system.
Before adding refrigerant when the cause of low
level is not known, the system should be tested for
leaks.
Assuming that leaks have been corrected without
discharging the system. proceed with partial
charge.
install and connect manifold gauge set.
(1) Close both gauge set manifold valves.
(2) Connect the suction gauge test hose to the
suction port of the compressor. Connect the
discharge gauge test hose to the discharge
port.
(3) Connect one end of long test hose to center
manifold outlet, other end to refrigerant dis-
pensing manifold.
(4) Close two dispensing manifold valves and
open remaining dispensing manifold valve.
Remove protective cap from opened valve.
(5) Screw a can of R-12 to the opened manifold
valve. Be sure gasket is in place and in good
condition. Tighten refrigerant can and manifold
locking nut to insure a good seal. Do not
over-tighten. 8 to 11 Nm (6 to 8 ftlbs.) is
sufficient if gasket is in good condition.
(6) Turn manifold valve (above the refrigerant can)
completely clockwise to puncture the can. This
closes the valve and seals the refrigerant in the
can.
Caution
Never heat small cans of refrigerant over 52°C
(125°F) as they may explode.
(7) Place the refrigerant in a large pan of water
heated to 52°C (125°F). Place pan of water
containing the refrigerant can on an accurate
scale so the Zimount of refrigerant added can
be -weighed. Open the refrigerant manifold
valve.
(8) Purge all air from test hoses. Air in the system
will be trapped in the condenser causing
abnormally high discharge pressures and inter-
fering with condensing of the refrigerant.
(8) Slightly loosen both test hoses at the gauge set
manifold. Tighten the hoses as soon as the air
is purged.
(10)Siightly looseo charging hose connection at
gauge set manifold. This will purge air from the
charging hose.
Tighten connection as soon as air is purged.