ACTUATOR MOTORS (VACUUM) · 6

ACTUATOR MOTORS (VACUUM) · 6

1991-Montero-Service-Manual · electrical system uniform inspection guidelines · страница 6 из 52 · Открыть оригинал PDF ↗

Connector melted ........A ........... (1) Require repair or
replacement.
Connector missing .......C ............ Require replacement.
Inoperative .............A ........ (2) Require replacement.
Linkage bent, affecting
performance ............A ... Require repair or replacement
of linkage.
Linkage bent, not
affecting performance ..2 ... Suggest repair or replacement
of linkage.
Linkage binding, affecting
performance ............
A ... Require repair or replacement
of linkage.
Linkage binding, not
affecting performance ..
1 ... Suggest repair or replacement
of linkage.
Linkage broken ..........A ... Require repair or replacement
of linkage.
Linkage loose, affecting
performance ............A ... Require repair or replacement
of linkage.
Linkage loose, not
affecting performance ..1 ... Suggest repair or replacement
of linkage.
Linkage missing .........C ............ Require replacement.
Linkage noisy ...........2 .. Suggest repair or replacement.
Missing .................C ............ Require replacement.
Terminal broken .........A .. Require repair or replacement.
Terminal burned, affecting
performance ............A ........... (1) Require repair or
replacement.
Terminal burned, not
affecting performance ..
1 ........... (1) Suggest repair or
replacement.
Terminal corroded,
affecting performance ..
A .. Require repair or replacement.
Terminal corroded, not
affecting performance ..1 .. Suggest repair or replacement.
Terminal loose, affecting
performance ............B .. Require repair or replacement.
Terminal loose, not
affecting performance ..1 .. Suggest repair or replacement.
Missing .................C ............ Require replacement.
Noisy ...................2 .. Suggest repair or replacement.
Out of adjustment .......B .. Require repair or replacement.
Таблица в оригиналеТаблица: оригинал страницы 6

(1) - Determine cause and correct prior to repair or
replacement of part.

(2) - Inoperative includes intermittent operation or out of OEM
specification.

ACTUATOR MOTORS (VACUUM)

ACTUATOR MOTOR (VACUUM) INSPECTION

Condition Code Procedure
Attaching hardware
broken ................. A ... Require repair or replacement
of hardware.
Attaching hardware
missing ................ C .......... Require replacement of

Оригинальная страница руководства
Connector melted ........ A ........... ( 1) Require repair or
100%

Назад