1991-Montero-Service-Manual · electrical system uniform inspection guidelines · страница 14 из 52 · Открыть оригинал PDF ↗
| hardware. | |
|---|---|
| Attaching hardware not | |
| functioning ............ | A ... Require repair or replacement |
| of hardware. | |
| Bulb seized in socket ... | A .. Require repair or replacement. |
| Burned, affecting | |
| performance ............ | A ........... (1) Require repair or |
| replacement. | |
| Burned, not affecting | |
| performance ............ | 2 ........... (1) Suggest repair or |
| replacement. | |
| Broken .................. | A .. Require repair or replacement. |
| Connector broken ........ | A .. Require repair or replacement. |
| Connector missing ....... | C ............ Require replacement. |
| Connector (Weatherpack | |
| type) leaking .......... | A .. Require repair or replacement. |
| Connector melted ........ | A ........... (1) Require repair or |
| replacement. | |
| Corroded, affecting | |
| performance ............ | A .. Require repair or replacement. |
| Corroded, not affecting | |
| performance ............ | 2 .. Suggest repair or replacement. |
| Leaking ................. | A .. Require repair or replacement. |
| Melted .................. | A ........ (2) Require replacement. |
| Shorted ................. | A .. Require repair or replacement. |
| Terminal broken ......... | A .. Require repair or replacement. |
| Terminal burned, affecting | |
| performance ............ | A ........... (2) Require repair or |
| replacement. | |
| Terminal burned, not affecting performance .. | 2 .. Suggest repair or replacement. |
| Terminal corroded, affecting performance .. | A .. Require repair or replacement. |
| Terminal corroded, not | |
| affecting performance .. | 2 .. Suggest repair or replacement. |
| Terminal loose, affecting performance ............ | B .. Require repair or replacement. |
| Terminal loose, not | |
| affecting performance .. | 1 .. Suggest repair or replacement. |
(1) - Determine cause and correct prior to repair or
replacement of socket.
(2) - Determine cause and correct prior to replacement of part.
BULBS, SEALED BEAMS AND LEDS
NOTE: Does not include soldered-in components.
BULB, SEALED BEAM AND LED INSPECTION
Condition Code Procedure
Adjustment out of
specification .......... B .. Require repair or replacement.
Application incorrect ... B ........ (1) Require replacement.
Attaching hardware
broken ................. A ... Require repair or replacement
of hardware.
Attaching hardware
missing ................ C .......... Require replacement of
hardware.
Attaching hardware not