1991-Montero-Service-Manual · electrical system uniform inspection guidelines · страница 12 из 52 · Открыть оригинал PDF ↗
| missing ................ | C .......... Require replacement of |
|---|---|
| hardware. | |
| Attaching hardware not | |
| functioning ............ | A ... Require repair or replacement |
| of hardware. | |
| Connector broken ........ | A .. Require repair or replacement. |
| Connector melted ........ | A ........... (1) Require repair or |
| replacement. | |
| Connector missing ....... | C ............ Require replacement. |
| Insulation damaged, | |
| conductors exposed ..... | A ........... (2) Require repair or |
| replacement. | |
| Insulation damaged, conductors not exposed . | 1 ............ Suggest replacement. |
| Open .................... | A .. Require repair or replacement. |
| Protective shield | |
| (conduit) melted ....... | 2 ........... (1) Suggest repair or |
| replacement. | |
| Protective shield (conduit) missing ...... | 2 .. Suggest repair or replacement. |
| Resistance (voltage drop) out of specification ... | A .. Require repair or replacement. |
| Routed incorrectly ...... | B ................. Require repair. |
| Secured incorrectly ..... | B ................. Require repair. |
| Shorted ................. | A .. Require repair or replacement. |
| Terminal broken ......... | A .. Require repair or replacement. |
| Terminal burned, affecting | |
| performance ............ | A ........... (1) Require repair or |
| replacement. | |
| Terminal burned, not affecting performance .. | 2 .. Suggest repair or replacement. |
| Terminal corroded, | |
| affecting performance .. | A .. Require repair or replacement. |
| Terminal corroded, not | |
| affecting performance .. | 2 .. Suggest repair or replacement. |
| Terminal loose, affecting | |
| performance ............ | B .. Require repair or replacement. |
| Terminal loose, not | |
| affecting performance .. | 1 .. Suggest repair or replacement. |
| Voltage drop out of | |
| specification .......... | A .. Require repair or replacement. |
(1) - Determine cause and correct prior to repair or
replacement of part.
(2) - Exposed conductor at replacement (aftermarket) terminal
end does not require repair or replacement.
BATTERY HOLD DOWN HARDWARE
See BATTERY TRAYS AND HOLD DOWN HARDWARE.
BATTERY TRAYS AND HOLD DOWN HARDWARE
BATTERY TRAY AND HOLD DOWN HARDWARE INSPECTION
Condition Code Procedure
Battery improperly
secured ................ 2 ................. Suggest repair.
Bent, affecting
performance ............ A .. Require repair or replacement.
Bent, not affecting