Purge Control Solenoid Valve Inspection NOTE
When disconnecting the vacuum hose, make an identification
markonso that it canbereconnectedtotheoriginal
position.
(1) Disconnect the vacuum hose (black with red stripe) from
the solenoidvalve
(2) Disconnect theharness connector

(3) Connect a hand vacuum pump to the nipple to which the
red-stripedvacuumhose was connected
(4) Apply a vacuum and check for air-tightness when voltage
isapplied directly to the purge-control solenoid valve and
when the voltage isdiscontinued,
Распознанный текст таблицы — требует сверки с оригиналом
| Battery voltage | Normal condition |
|---|---|
| When applied | Vacuum leaks |
| When discontinued | Vacuum is maintained |
(5)Measurethe resistance betweentheterminalsofthe
solenoid valve
Standard value:36_44 02 [at 20*C (68PF1]
SIMPLE CHECKINGOF THE TWO-WAY VALVE

Attacha clean hose and check the operation of the two-
way valve
Распознанный текст таблицы — требует сверки с оригиналом
| Inspection procedure | Normal condition |
|---|---|
| Lightly blow from inlet side (fuel tank side): | Air passes through slight feeling with of resistance_ |
| Lightly blow from outlet side (canister side): | Air passes through. |
AIRFLOWSENSOR;ENGINE COOLANTTEMPERATURE
SENSORANDINTAKEAIRTEMPERATURE SENSOR IN-
SPECTION
Refer to GROUP13.
CANISTER INSPECTION
Refer to GROUP13.
EXHAUST EMISSION CONTROL SYSTEMEI7FCBL
AIRFUELRATIO CONTROL SYSTEM
Toinspecttheair-fuelratiocontrolsystem,referto
GROUP 13
For detailed information concerning the illumination pat-
tern of the malfunction-indicator light and other aspects of
the self-diagnosis function, refer to GROUP13
PWJE9086-E