2002 · FUEL [13] · страница 61 из 68 · Открыть оригинал PDF ↗




ENGINECOOLANTTEMPERATURESENSOR CHECK
1.Removetheenginecoolanttemperaturesensor.
2.Measuretheresistancebetweentheterminalsofthe
connectors while immersing the sensor part of the engine
coolanttemperaturesensorinthehotwater.
Standardvalue:
2.1-2.7kΩ(at20_C)
0.26-0.36kΩ(at80_C)
3.Iftheresistanceisnotwithintherangeofthestandard
value,replacetheenginecoolanttemperaturesensor.
4.Applythesealanttothethreadoftheenginecoolant
temperaturesensorandtightenittothespecifiedtorque.
Sealant:
3MNutLockingPartNo.4171orequivalent
Tighteningtorque:36±6N·m
EGRVALVEPOSITIONSENSORCHECK
1.DisconnecttheEGRvalvepositionsensorconnector.
2.MeasuretheresistancebetweentheEGRvalveposition
sensorsideconnectorterminalNo.2andterminalNo.
3.
Standardvalue:3.5-6.5
kΩ
3.InstallahandvacuumpumptotheEGRvalvenipple.
4.MeasuretheresistancebetweentheEGRvalveposition
sensor-sideconnectorterminalNo.1andterminalNo.
3whenanegativepressureisapplied.
Normalcondition:
Slowly increase the negativeChanges smoothly in
pressure to 60 kPa.proportion to the negative
pressure
5.Iftheresistanceisoutsidethestandardvalue,orifit
doesn’t change smoothly,replace theEGRvalve position
sensor.