Диагностика и устранение неисправностей · 8

TROUBLESHOOTING · 8

MANUALS · SUPPLEMENTAL RESTRANT SYSTEM (SRS) [52B] · страница 8 из 48 · Открыть оригинал PDF ↗

Текст распознан со скана. Числа и обозначения можно сверить с оригиналом ниже.

INSPECTION PROCEDURE CLASSIFIEDBY DIAGNOSTIC TROUBLE

Code No: 11, 12 or 13Front impact sensor system

{Comment)
(1)These diagnosis codes are output if there is abnormal resistance between the input terminals of
the SDU front impact sensor:
The trouble causes for each code No. are &s follows_

Probable cause

Malfunction of front impact sen-
sor
Malfunction of harnesses Or con-
nectors
Malfunction of SDU

Таблица в оригиналеТаблица: оригинал страницы 8
Распознанный текст таблицы — требует сверки с оригиналом
Code NoTrouble Symptom
Short in front impact sensor or harness short
Short in front impact sensor Or air bag module (squib} harnesses leading to the
vehicle body
earth
Short in front impact sensor or air bag module (squib} harnesses leading to the
power supply
12Open circuit in either left or right front impact sensor or open harness
Short in front impact sensor or air bag module (squib} harnesses leading to the
power supply
13Open circuit in both left &d right front impact sensors or open harness
Short in front impact sensor Or air bag module (squib} harnesses leading to the
power supply

Diagnosis codes 11, 12and13 are sometimes generated in combination wvith malfunction
codes relating to the airbagmodule (squib} (code Nos. 21 ad 22},but sometimes only
one may be output instead of bothbeing memorised.Because Of thisthe airbagmodule
should also be inspectedat thesame time
The relationships between the codes are as follows

Таблица в оригиналеТаблица: оригинал страницы 8
Распознанный текст таблицы — требует сверки с оригиналом
ShortFront impact sens
Open circuit
sensor)
or
Open circuit
(2 sensors)
Air bag module (squib)Shortor 2112 or 2113 or 21
Open circuit11 Or 2212 0r 2213 0r 22
Иллюстрация 1, страница 8

Turn the ignition key to the "LOCKposition, disconnect
the negative battery cable and tape the terminal:

Caution

Wait at least 60 seconds after disconnecting the bat-
tery cable before doing any further work: (Refer to
P 52B-4)

Remove the floor console assembly: (Refer to GROUP
52AFloor Console:}

Place a flat-tipped (~) screwdriver against the lock spring
(metal portion) of the SDU connector lock lever; and push
the spring horizontally toward the inside of the unit

Caution

Do not use excessive force to raise the lock lever
(green)_

Do not insert the screwdriver into the gap between
the lock lever (green) and the lock spring (metal
portion)

Disconnect the red14-pin connector from the SDU.

ADDED

Оригинальная страница руководства
Страница 8
100%

Назад
Сверху