BLOWER ASSEMBLY · 22 — Pajero II 1991–1998 — руководство по ремонту

BLOWER ASSEMBLY · 22

BLOWER ASSEMBLY · 22

MANUALS · HEATER, AIR CONDITIONER AND VENTILATION [55] · страница 22 из 118 · Открыть оригинал PDF ↗

Текст распознан со скана. Числа и обозначения можно сверить с оригиналом ниже.

Проверка

ESSKCAM

Check for bending or abnormal deflection of the rotating
shaft of the blower motor assembly.

Check for damage to the fan.

Check for damage of the blower case.
Checktheoperationoftheinsideloutsideair-selection
damper, and for damage_

BLOWER MOTOR ASSEMBLY CHECK

Иллюстрация 1, страница 22

(1) Connect the blower motor terminals directly to the bat-
tery and check that the blower motor operates smoothly.
(2)Next,reversethepolarityandcheckthattheblower
motor operates smoothly in the reverse direction.

RESISTOR CHECK

Usinga circuit tester,measure the resistance between the
terminals indicated below

Theconditioncanbeconsidered satisfactoryifthevalue
measured at this time is equivalent to the standard value.

Standard value

Таблица в оригиналеТаблица: оригинал страницы 22
Распознанный текст таблицы — требует сверки с оригиналом
Terminals measuredStandard value 9
Between terminalsApprox: 1.96 + 7%
Between terminalsApprox: 0.95 # 7%
Between terminalsApprox: 0.33 * 7%

SERVICE POINT OF INSTALLATION

ESSKDAF

10. INSTALLATION OF AIR SELECTION CONTROL WIRE

Connect the air selection control wire to the air selection
damper lever by following the steps below.
(1) Move the air selectioncontrol lever totheposi-
tion

(2)With the air selection damper lever pressed inward in
thedirectionindicatedbythearrow,connectthe
inner cableof theair selectioncontrolwireto the
end of the air selection lever, and then secure outer
cable byusingclip.

Mitsubishi Motors CorporationFeb1991

Оригинальная страница руководства
Страница 22
100%

Назад
Сверху