AND AIR-INLET SENSOR
AIR-THERMO SENSOR
Disconnect the sensor's connector at the evaporator case and
byusingan ohmmeter, measure the resistance. If the resistance
is within 10% of value of the characteristic curve, the sensor is
functioning normally:
ENGINE COOLANT TEMPERATURE SWITCH
<For air conditioner switch off>

(1) Diptheengine coolant temperatureswitchinoiland
heat the oil withgas burner or similar item.
(2)Whentheoiltemperaturereachesthestandard value,
check that there is no continuity between the switch ter-
minals:
Standard value:<Except 4056 engine>
More than 112-118PC (234-244PF)
<4056>
More than 114-1188C (237-2449F)
<For condenser fanz
(1) Diptheenginecoolanttemperatureswitchinoilas
shown in the illustration_
(2) Check the continuity witha circuit tester as the tempera-
ture of the oil changes, and the condition is normal if the
continuity is within the following ranges_
<4056>
Распознанный текст таблицы — требует сверки с оригиналом
| Item | Standard value |
|---|---|
| Continuity (temperature at point AV} | More than 99-1058C (210-221*F) |
| No continuity (temperature at point B) | Less than 97*C (206*F) |
<4M4O>
Распознанный текст таблицы — требует сверки с оригиналом
| Item | Standard value |
|---|---|
| Continuity | More than |
| (temperature at point A) | 101-105*C (214-221*F) |
| No continuity | Less than |
| (temperature at point B) | 98*C (208PF) |