Wave Pattern Inspection Using an Analyzer
Measurement method
(1)Disconnect the air flow sensor connector; and connect the
special tool (test harness: MB991348) in between. (All
terminals should be connected:)
(2) , Connect the analyzer special patterns pickup to terminal
of the air flow sensor connector:
Standard wave pattern


7Fuii9o
Observation conditions (from conditions on above engine speed is increased by racing:)


Wave pattern observation points
Check that cycle time T becomes shorter and the frequency
increases when the engine speed is increased