OXYGEN SENSOR <6G74-SOHC 24 VALVE ENGINE> · 77 — Pajero II 1991–1998 — руководство по ремонту

OXYGEN SENSOR <6G74-SOHC 24 VALVE ENGINE> · 77

OXYGEN SENSOR <6G74-SOHC 24 VALVE ENGINE> · 77

Pajero II Workshop Manual 1998 Supplement · FUEL · страница 77 из 104 · Открыть оригинал PDF ↗

Текст распознан со скана. Числа и обозначения можно сверить с оригиналом ниже.

Иллюстрация 1, страница 77
Иллюстрация 2, страница 77

SENSOR INSPECTION <OXYGEN SENSOR (FRONT)>
Disconnect the oxygen sensor connector:
Check that there is continuity [4.58.02 at 20*C]
between oxygen sensor connector terminaland
terminal

(3)If there is no continuity, replace the oxygen sensor:

(4)Warm the engine until the engine coolant temperature
reaches 80'C or more

5)Use the jumper leads to connect the oxygen sensor
terminal 0 (connect (+) terminal) and terminal
(connect (~) terminal) to the batteryand (~) terminals
respectively:

Caution

Be caretul when connecting the jumper leads, as
connecting the terminals incorrectly will damage the
oxygen sensor:

(6) Connectdigital-type voltmeter to terminaland
terminal @-

While repeatedly racing the engine, measure the oxygen
sensor output voltage_

Таблица в оригиналеТаблица: оригинал страницы 77
Распознанный текст таблицы — требует сверки с оригиналом
EngineOxygen sensor
output voltage
Notes
When racing the
engine
0.6_ 1.0 VWhen the airlfuel mix-
ture ratio is enriched
by racing the engine
repeatedly, a normal
oxygen sensor will
voltageof
output a
0.6-1.0v.

NOTE

For removal and installation of the oxygen sensor; refer to
GROUP 15Exhaust PipeMain Muffler and Catalytic
Converter:

Оригинальная страница руководства
Страница 77
100%

Назад
Сверху