Pajero II Workshop Manual 1998 Supplement · FUEL · страница 86 из 104 · Открыть оригинал PDF ↗
Текст распознан со скана. Числа и обозначения можно сверить с оригиналом ниже.


Wave pattern observation points
7Fui204
Check that the standard wave pattern appears when the stepper motor is operating:
(Point A): Presenceor absence of induced electromotive force from themotor turning: (Refer to the
abnormal wave pattern._
Contrast with standard wave patternProbable cause
Induced electromotive force does not appear or is extremely small:Motor is malfunctioning
(Point B): Height of coil reverse electromotive force
Contrast with standard wave pattern
Coil reverse electromotive force does not appear or is extremely small:
Probable cause
Short in the coil
Abnormal wave pattern
Cause of problem
Motor is malfunctioning: (Motor is not operating-)
Wave pattern characteristics
Induced electromotive force from the motor turning does
not appear: