Pajero II Workshop Manual 1998 Supplement · FUEL · страница 83 из 104 · Открыть оригинал PDF ↗
Текст распознан со скана. Числа и обозначения можно сверить с оригиналом ниже.
Checking the Injection Condition
1) Following the steps below; bleed out the residual pressure
within the fuel pipe line to prevent flow of the fuel.
Remove the injector:
Arrange the special tool (injector test set) , adaptor, fuel
pressure regulator and injector test clip as shown in the
illustration below:


Connect the battery's negative (~) terminal.
Apply battery voltage to the fuel pump check terminal and
activate the fuel pump
(6) Activate the injector and check the atomized spray
condition of the fuel;The condition can be considered
satisfactory unless it is extremely poor:
Stop the actuation of the injector; and check for leakage
from the injector's nozzle_
Standard value: 1 drop or less per minute
(8)Activatetheinjector without activating the fuel pump;
then, when the spray emission of fuel from the injector
stops. disconnect the special tool and restore it to its
original condition.