1984 · Электрооборудование — страница 66

POWERWINDOWS · 66

1984-Montero · electrical a · страница 66 из 169 · Открыть оригинал PDF ↗

Иллюстрация 1, страница 66

cl -+

POWERWINDOWS

SymptomProbable causeRemedy
None of the door windows
will
operate
Burnt-out main fu.sible linkReplace the main fusible link and
isolate cause
Burnt-out
sub f&:ible link
Replace the sub fusible link and
isolate cause
Burnt-out
fuse
Replace the fuse and isolate cause
Correct grounding
Replace the relay
Replace the main switch
Break in harness, or poor connectionCorrect or replace the harness
The front door windows
cannot be
operated by using the main switches
Malfunctioning
main switch
Replace the main switch
Break in harness, or poor connectionCorrect or replace the harness
Malfunctioning
motor
Replace motor
The door windows
can be operated
by using the main switches, but
Malfunctioning
main switch
Replace the main switch
cannot be operated by using the :
sub switches
Malfunctioning
sub switch
Replace the sub switch
Break in harness, or poor connectionCorrect or replace the harness
The door windows
can be operated
even though the lock switch is
at “ON”
Malfunctioning
main switch
Replace the main switch
Таблица в оригиналеТаблица: оригинал страницы 66
Иллюстрация 2, страница 66
Иллюстрация 3, страница 66
Иллюстрация 4, страница 66
Иллюстрация 5, страница 66
Иллюстрация 6, страница 66
Иллюстрация 7, страница 66
Иллюстрация 8, страница 66
Иллюстрация 9, страница 66
Иллюстрация 10, страница 66
Иллюстрация 11, страница 66
Иллюстрация 12, страница 66
Иллюстрация 13, страница 66
Иллюстрация 14, страница 66
Оригинальная страница руководства
cl-+ TROU13LESHOOTING
100%

Назад
Сверху