Testing Commutator Runout

1. Place armature in a pair of “V” blocks and check runout
with a dial indicator.

2. Check both shaft and commutator. A bent shaft requires
replacement of armature.

,3. If commutator runout exceeds 0.05 mm (002 in.),
commutator should be refaced. Remove only enough
metal to provide a smooth; even surface. /

Commutator runout . . . ‘. . . Max 0.05 mm (.002 in.)
Under cut depth . . . . . . . . . . . . . . . 0.5 mm (.02 in.)

Иллюстрация 2, страница 94

TESTING FIELD COILS FOR GROUNDING

1. Touch one probe of test lamp to series field coil lead
and other probe to yoke. Lamp should not light.
If lamp lights, coils are grounded. If field coils are ground-
ed, replace field coil and yoke assembly.

Иллюстрация 3, страница 94
Иллюстрация 4, страница 94

TESTING BRUSH HOLDER

1. Touch. each of the insulated brush holders with one test
probe, while holding other test probe against brush
holder plate.

2. The lamp should not light during this test since the brush
holders are insulated. If the lamp lights brush holders
on brush holder plate are grounded. Replace brush
holder assembly if brush holders are grounded.