1984 · Электрооборудование — страница 93

BRUSHES AND SPRINGSREPI;ACEMENT · 93

1984-Montero · electrical a · страница 93 из 169 · Открыть оригинал PDF ↗

Иллюстрация 1, страница 93

III -+

BRUSHES AND SPRINGSREPI;ACEMENT

1. Brushes that are worn beyond wear limit line, or are

oil-soaked, should be replaced.

2. When replacing field coil brushes, crush worn brush with
pliers, taking care not to damage pigtail.

Иллюстрация 2, страница 93

TESTING ARMATURE Testing Armature for Short Circuit

1. Place armature in a growler.

2. Hold a thin steel blade parallel and just above while
rotating armature slowly in growler. A shorted armature
will cause blade to vibrate and be attracted to the core.
Replace shorted armature.

Иллюстрация 3, страница 93
Иллюстрация 4, страница 93
Иллюстрация 5, страница 93

Testing Armature for Grounding

1. Touch armature coil core and the end of each commu-

Иллюстрация 6, страница 93