Pajero II Workshop Manual 1991 · Электрооборудование двигателя · страница 21 из 54 · Открыть оригинал PDF ↗
Текст распознан со скана. Числа и обозначения можно сверить с оригиналом ниже.
RESISTIVE CODE INSPECTION
Measure the resistance of the high tension cable and all spark
plug leads_
(1) Checkcapand coating for cracks.
(2) Measure resistance_
Limit: Max: 26 kS2
IGNITION COIL INSPECTION

<4G64, 6G72-12 VALVE>
(1)Measurement of the primary coil resistance
Measure the resistance of the positive+) terminal and
negative (~) terminal of the ignition coil.
Standard value:0.72-0.88 $2
(2) Measurement of the secondary coil resistance
Measure the resistance between the ignition coil's posi-
tive+) terminal and the high tension terminal:
Standard value:10.29-13.91kn
<6G74,6G72-24 VALVE>
(1)Measurement of the primary coil resistance_
Measure the resistance between the terminals for each cylinder
(No.1-No.4,No.2-No5, No. 3-No. 6) of the ignition coil as
shown in the illustration
Standard value: 0.69-0.85 n
(2)Measurement of the secondary coil resistance_
Measure the resistance between the high-voltage terminals for
each cylinder (No.1 - No.No; 2-No. 5, No. 3-No. 6) of the
ignition coil as shown in the illustration.
Standard value: 15.3-20.7 kn
POWER TRANSISTOR INSPECTION
<4G64, 6G72-12 VALVE>
NOTE

Mitsubishi Motors CorporationJun: 1994
An analogue type of circuit tester shouldbe used.
2Connect the circuit tester (~) probe (black) to terminal (3).
(1) Connect the negative (~) terminal of the 1.5V power supply
to terminal (2) of the power transistor: then check whether
there is continuity between terminal (3) ad terminal (2)
whenterminal (1)andthe positive71terminalare
connected and disconnected
Terminal (1) and (+ ) terminal
Распознанный текст таблицы — требует сверки с оригиналом
| Terminal (1) and (+ ) terminal | Terminal (3) and termi- nal (2) |
|---|---|
| Connected | Continuity |
| Unconnected | No continuity |
(21) Replace thepower transistor if there isa malfunction.
PWJE9086-FREVISED