1987-Montero · Vol2 a · страница 118 из 284 · Открыть оригинал PDF ↗

4. Check pinion to stopper clearance (pinion gap) with a feeler
gauge.
Standard value : 0.5-2.0 mm (.020-.079 in.)



5. If pinion gap is out of specification, adjust by adding or remov-
ing gaskets between magnetic switch and front bracket.



lEL113
PULL-IN TEST OF MAGNETIC SWITCH
1. Disconnect field coil wire from M-terminal of magnetic switch.
2. Connect a 12V battery between S-terminal and M-terminal.
Caution
This test must be performed quickly (in less than 10 sec-
onds) to prevent coil from burning.
/
Field coil wire 3. If pinion moves out, then pull-in coil is good. If it doesn’t,
replace magnetic switch.
HOLD-IN TEST OF MAGNETIC SWITCH
1. Disconnect field coil wire from M-terminal of in;ignetic switch.
2. Connect a 12V battery between S-terminal and body.
Caution
This test must be performed quickly (in less than 10 sec-
onds) to prevent coil from burning.
3. If pinion remains out, everything is in order. If pinion moves in,
Field coil wire hold-in circuit is open. Replace magnetic switch.
This test must be performed quickly (in less than 10 sec-
onds) to prevent coil from burning.