WAiER VALVE REPLACEMENT · 244

WAiER VALVE REPLACEMENT · 244

1987-Montero · Vol2 a · страница 244 из 284 · Открыть оригинал PDF ↗

Иллюстрация 1, страница 244

WAiER VALVE REPLACEMENT

N24FBAC

I. Set the temperature control lever to the extreme right
position.
2. Remove the radiator drain plug, and then drain the engine
coolant.

3. Remove the air filter
4. Remove the heater hose clamp to disconnect the heater
hose.

Иллюстрация 2, страница 244
Иллюстрация 3, страница 244

5. Disconnect the water valve control wire from the blend air
damper lever and the heater unit’s clip.
6. Remove the water valve cover.

Иллюстрация 4, страница 244
Иллюстрация 5, страница 244
Иллюстрация 6, страница 244
Иллюстрация 7, страница 244

7. Remove the piping clamp.
8. Unfasten the clip of blend air damper lever, and disconnect
the link for the water valve lever from the blend air damper
lever.
9. Remove the joint hose clamp.
10. Cut the joint hose.

11. Remove the water valve from the heater core.
12. Apply a coating of soapy water to the inside surface of the
new joint hoses, and then connect them to the pipe part of
the water valve and the heater core.
13. Connect the link, and then install the heater cover.

Иллюстрация 8, страница 244
Иллюстрация 9, страница 244
Иллюстрация 10, страница 244
Иллюстрация 11, страница 244
Иллюстрация 12, страница 244
Иллюстрация 13, страница 244
Иллюстрация 14, страница 244
Иллюстрация 15, страница 244
Иллюстрация 16, страница 244
Иллюстрация 17, страница 244
Иллюстрация 18, страница 244
Оригинальная страница руководства
24-8 HEATERS - Service Adjustment Procedures
100%

Назад
Сверху