PULSE GENERATOR
REMOVAL AND INSTALLATION
NOBRJM











Removal steps
I. Pulse generator
2. O-ring

NOTE
(1) Reverse the removal procedures to reinstall
(2) q : Non-reusable parts

l Check whether or not metal particles are adhered to the
pole (iron core) of the pulse generator.
l Check whether or not the installation bolts of the pulse
rotor or the pulse generator are loose.
(For detailed information concerning the pulse rotor, refer
to GROUP 21 TRANSMISSION - Transfer.)


CHECKING PULSE GENERATOR RESISTANCE
Check whether or not the resistance between the terminals
shown in the figure is within the standard value range.
Standard value : 215 - 275 LR
If the resistance is not within the standard value range, replace
the pulse generator.