1987-Montero · Vol2 a · страница 123 из 284 · Открыть оригинал PDF ↗

REPLACEMENT OF BRUSHES AND SPRINGS


3. Sand pigtail end with sandpaper to ensure good soldering.
4. Insert pigtail into hole provided in new brush and solder it.
Make sure that pigtail and excess solder do not come out onto
brush surface.

TESTING ARMATURE FOR GROUNDING
Check the insulation in the space between the segments of the
commutator and the armature and coil core. If there is no conduc-
tivity this is normal.




CHECKING CIRCUIT BREAK BETWEEN ARMATURE AND COIL
Check conductivity between each segment. If there is conductiv-
ity this is normal.