Adjustment of the Blend Air Damper · 243

Adjustment of the Blend Air Damper · 243

1987-Montero · Vol2 a · страница 243 из 284 · Открыть оригинал PDF ↗

Иллюстрация 1, страница 243

1. Move the temperature control lever from its extreme left
position to its extreme right position and check to be sure
that it moves correctly and smoothly to each position.
2. Then move the temperature control lever to the extreme
left position, and check to be sure that warm air does not
come out when the blower is operated.
3. If the air flow is not correct in the above step, adjust the
temperature control wire.

Иллюстрация 2, страница 243

Adjustment of the Blend Air Damper

I. Move the warm water flow control lever to the extreme left
position.
2. Disconnect the water valve control wire from the blend air
damper lever and the heater unit’s clip.
3. Remove the water valve cover.

Иллюстрация 3, страница 243
Иллюстрация 4, страница 243
Иллюстрация 5, страница 243

4. Unfasten the clip of the blend air damper lever, and
disconnect the link for water valve lever from the blend air
damper lever.

Иллюстрация 6, страница 243

7. Attach the end of the link for the water valve lever to the
blend air damper lever.
8. Install the water valve cover.
9. After connecting the water valve control wire to the blend
air damper lever, connect to the clip part of the heater unit.

Caution

Be careful that the lever does not move when clipping.

10. Check to be sure that the temperature control lever
operates smoothly at each position. Also check to be sure
that the blend air damper is completely closed when the
temperature control lever is moved to the extreme left
position and the extreme right position.

Иллюстрация 7, страница 243

1 STB Revision

Оригинальная страница руководства
HEATERS - Service Adjustment Procedures 24-7