1987-Montero · Vol2 a · страница 251 из 284 · Открыть оригинал PDF ↗

HEATERS - Blower Assembly
5. REMOVAL OF BLOWER ASSEMBLY
(1) Disconnect the connector of the front wiring harness
(connected to the resistor).
(2) Remove the ground installation bolt. (Tightened togeth-
er with the blower assembly.)
(3) Remove the blower assembly installation bolt.

INSPECT00 N24KCAD
RESISTOR
Connect an ohmmeter to each terminal of the resistor and
measure the resistance.
| Terminal connections | Resistance |
|---|---|
| 1 -2(M1) | Approx. 1.22R |
| 1 -3(M2) | Approx. 0.41 R |
| I-4(Low) | Approx. 2.25112 |
| 1 - 5 (High) | Approx. OlR |
BLOWER MOTOR
(1) Connect the blower motor terminals directly to the battery
and check that the blower motor operates smoothly.
(2) Next, reverse the polarity and check that the blower motor
operates smoothly in the reverse direction.


SERVICE POINTS OF INSTALLATION N24KDAC 3. INSTALLATION OF AIR SELECTION CONTROL WIRE
Connect the air selection control wire to the air selection
damper lever by following the steps below.
(1) Move the air selection control lever to the& position.
(2) With the air selection damper lever pressed inward in
the direction indicated by the arrow, connect the inner
cable of the air selection control wire to the end of the
air selection damper lever, and then secure the outer
cable by using a clip.