1987-Montero · Vol2 a · страница 239 из 284 · Открыть оригинал PDF ↗

Диагностика и устранение неисправностей
N24EAAC
| Symptom | Probable cause | Remedy | Reference paw |
|---|---|---|---|
| Improper heat | Obstructed floor outlets | Correct | - |
| ’ Changeover dampers improperly adjusted or binding | Correct | 24-5 | |
| , Thermostat malfunction | Replace | - | |
| Obstructed heater hoses | Replace | 24-l 2 | |
| ’ Improperly adjusted control cables | Adjust | 24-5 | |
| Plugged or partially plugged heater core | Clean or replace | 24-l 3 | |
| No ventilation even when mode selection l i d | Incorrect adjustment of changeover dam- pers | Adjust | 24-5 |
| ever s operate | Incorrect installation mode selection control wire | Adjust | 24-5 |
| Ducts are incorrectly/incompletely con- netted, crushed, bent or clogged. | Repair or replace | - | |
| Blower motor oper- t hih d | Broken blower motor resister | Replace | 24-l 5 |
| aes on g spee only | Broken blower switch | Replace | 24-l 0 |
| Blower motor inop- i | Burnt-out fuse | Replace | - |
| eratve | Poor grounding | Correct | - |
| Malfunction blower switch | Replace | 24-l 0 | |
| Malfunction blower motor | Replace | 24-l 4 |