1989-Mitsu-Factory Manual · fuel system · страница 39 из 53 · Открыть оригинал PDF ↗
25. REMOVAL OF SLOW CUT SOLENOID VALVE
(1) Remove the retainer and pull out the slow cut solenoid
valve.
Cautioon
When removing the valve, do not hold the leads but
hold the body.
(2) Using a screwdriver or other tool with a thin flat end.
push the stopper section and remove the two termi-
nals from behind the connector.
Caution

Ensure that the terminal is not bent during removal
of the connector.

29. REMOVAL OF BIMETAL ASSEMBLY
(1) Grind away the head of the two rivets of the bimetal
assembly using an hand grinder or other tool. remove
the screw.
(2) Remove the plate, the bimetal assembly and the
packing.
(3) Remove the remaining rivet bodies using a pin punch
etc..

(4) Using a screwdriver or other tool with a thin fiat end,
push the stopper section and remove the terminal
from behind the connector.
Caution

Ensure that the terminal is not bent during removal
of the conector.
59. REMOVAL OF MAIN AIR JET (PRIMARY)/54. PILOT JET
(PRIMARY)/55. PILOT JET (SECONDARY)
(1) When removing the jets, use a screwdriver that is an
exact fit for their slot and work carefully to prevent
damage.