1998 · FUEL [13] · страница 86 из 104 · Открыть оригинал PDF ↗
Текст распознан со скана. Числа и обозначения можно сверить с оригиналом ниже.

Wave pattern observation points

Check that the standard wave pattern appears when the stepper motor is operating:
(Point A): Presence or absence of induced electromotive force from the motor turning: (Refer to the
abnormal wave pattern )
Распознанный текст таблицы — требует сверки с оригиналом
| Contrast with standard wave pattem | Probable cause |
|---|---|
| Induced electromotive force does not appear or is extremely small; | malfunctioning Motor is |
| Point B): Height of coil reverse electromotive force Contrast with standard wave pattem | Probable cause |
| Coil reverse electromotive force does not appear or is extremely small. | Short in (he coil |
(Point B): Height of coil reverse electromotive force
Abnormal wave pattern
Cause of problem
Motor is malfunctioning: (Motor is not operating )
Wave pattern characteristics
Induced electromotive force from the motor turning does
not appear: