Use the multi-use testerOrMUT-II to force-drive the ac
tuator,and turn the wheel by hand to check the change
in braking force when the brake pedal is depressed.
Theresult should beas shown in thefollowing illustra-
tion
NOTE
When the multi-use tester or MUT-II is used and the
ABS system is selected, the ABS system will switch
to multi-use tester mode and the ABS warning lamp
will illuminate_
When the ABS function has been interrupted by the
fail-safe, the multi-use tester or MUT-II actuator test-
ing cannot be used.


If a different result is obtained when checking, correct it
by followingthe procedure inthe'Diagnosis Table for
Simple Inspectionbelow.
Diagnosis Table for Simple Inspection
Распознанный текст таблицы — требует сверки с оригиналом
| Diag | nosis | Cause | Sd d |
|---|---|---|---|
| Normal | Problem | uggeste remey | |
| The wheel will not lock even when the edal is | Blockage in the brake line outside the hydraulic unit | Inspect the brake line and clean | |
| After locking for a second period, the | p depressed. | Blockage in the oil pressure circuit in the hydraulic unit | Replace the hydraulic unit |
| braking force will release_ | Braking force does not release | Hydraulic unit brake pipes are incorrectly connected | Connect correctly |
| Hydraulic unit solenoid valve is defective | Replace the hydraulic unit |